Skip to content
HomeCineSolutionsFrance
EN
Quote
Contact
Account
Basket
€60
Back in stock soon
Delivery on 26 November 2026 (from €9.90)
Fast delivery: on 24 November 2026
Notify me when it's back in stock
Protect your product
+€10
Extended warranty to 5 years +
Accidental damage cover for 3 yearsWhat are the benefits?

Overview

In an ultrasonic cleaning machine, the water makes a round trip with each cycle: it leaves a removable tank, fills the basin where the record rotates, then returns to the tank once draining is complete. This genuine HumminGuru tank replaces the one in your machine if it is cracked, lost or clouded. You can also use it alongside the first to keep two separate batches of water, one for washing and the other for rinsing.

Four hundred millilitres with markings for each record size

The tank holds a maximum of 400 ml, the amount the cleaning basin can accommodate. Its wall has four graduations (100, 200, 300 and 400 ml) and two level marks. The first is for 30 cm and 25 cm records, the second for 17 cm 45 rpm records. These marks serve as a starting point. The correct water level just covers the smooth band between the last track and the label: the ultrasound then reaches the entire groove without wetting the paper. A thick, slightly warped record or one with an unusually sized label may require a few millilitres more or less. The graduations then help you use the right amount from one session to the next.

The lid has a removable holder for a water filter. This filter slides in folded in half and traps the larger particles loosened from the record during cleaning. The filter cartridge is not supplied with this tank: the one from your machine can be moved from one tank to the other. If you prefer to work without a filter, simply remove the holder from the lid.

The water’s journey between the tank and the cleaning basin

Fill the tank to the desired level, pour the water into the basin, then put the empty tank back into its slot on the side of the machine. The NOVA comes with a funnel for pouring water without splashing the mechanism. At the end of cleaning, draining returns the water from the basin to the tank in around forty seconds, before fan drying begins. The tank therefore also serves as a collection container. As it is transparent, you can see the condition of the used water at a glance: if it is cloudy or full of particles, it needs changing.

The machine checks that the tank and its lid are present before starting, and no cycle will run without them. On the NOVA, removing the tank during a programme turns on a steady red indicator light and stops the machine. It returns to standby as soon as the tank is put back in place.

Two tanks to separate washing and rinsing

With a single tank, the same water is used from one record to the next until it is replaced. A second tank changes how a session is organised. The first holds the cleaning water: distilled water with a few drops of surfactant, an agent that reduces the water’s surface tension so it reaches the bottom of the groove more easily. The second contains only distilled water. After cleaning and draining, swap the tanks and run a short cycle with clean water. This rinse removes the last traces of cleaning solution before drying, and each batch of water stays in its own tank from one session to the next.

This tank also serves as a spare part. Over the years, the plastic can become cloudy and lose the transparency that lets you monitor the water. A cracked tank or a lid that does not close properly lets water leak near the electronics. The same tank fits the original HumminGuru (HG01) and the NOVA (HG05): if you switch from one model to the other, your tanks remain usable.

Care and precautions for a plastic tank

Empty the tank after each session. Then rinse the body, lid, filter holder and filter itself with clean water and leave them to air-dry. Do not use a dishwasher, microwave or any other heat source. Heated plastic can warp, leaving the tank unable to fit properly into the machine.

The water you pour in must be cold or at room temperature, never hot. The ultrasound already raises the bath temperature over successive cycles, and the machine stops cleaning as soon as the water reaches 55 °C. Use distilled, demineralised or deionised water. Tap water, especially hard water, leaves deposits on records and in the internal pipes.

Technical specifications

Function and design

  • Official HumminGuru tank designed to supply water during vinyl record cleaning
  • Fully removable tank
  • Simplified filling and draining
  • Suitable for replacing an existing tank or for use alongside it

Compatibility

  • Compatible models: HumminGuru HG01 (Original), HumminGuru HG05 (NOVA)

Precautions for use

  • Do not heat
  • Do not microwave

Frequently asked questions

Does this tank fit other HumminGuru devices?

No. It is exclusively for the brand’s two ultrasonic cleaning machines, the original HG01 and the NOVA HG05.

What's the difference compared to the HumminGuru automatic water dispenser's tank?

The automatic water dispenser comes with its own 650 ml tank. This tank attaches beneath a USB-C rechargeable motorised body, which dispenses 350 ml for 25 and 30 cm, 400 ml for 17 cm, or the desired amount in manual mode. Its lid incorporates a suction filter, through which the water flows each time the pump runs. The tank shown here holds 400 ml and is filled by hand. Both fit into the HG01 and the NOVA.

Can a cleaning product be added to the water in the tank?

Yes. HumminGuru offers The Small Bottle, an alcohol-free surfactant formulated for its machines. It improves water penetration into the groove and speeds up drying: with it, 3 minutes of drying is generally enough. Other cleaning solutions should be avoided, as the machine’s warranty excludes damage caused by unauthorized chemicals.

When should the water filter be replaced?

The filter is washable: regular rinsing with clean water, followed by thorough air drying, extends its lifespan. It must be replaced when it becomes noticeably darker or its fibres wear out. When reassembling, check that the filter housing is securely reattached under the lid.

Can water be left in the tank between sessions?

It’s best to empty it. Before putting the machine away, drain the tray, empty the tank and wipe down its various parts. On the NOVA, the funnel is stored in the tank, which is then put back in the machine. Never move the machine while there is still water in the tray or tank.

Is the 17 cm mark sufficient for cleaning a 45 rpm record?

On the NOVA, the mark is only reliable when the 17 cm support is installed in the tank and the drive wheels are set to this size. The same principle applies to 25 cm records and their dedicated support. The maintenance tool supplied with the machine also serves as a gauge to check the level directly in the tank.

Why does water appear in the empty tank when no program has started?

On the NOVA, this happens when water is poured slightly outside the opening of the tank. Water running down the sides flows into an internal collector, designed to prevent leaks, then returns to the tank as soon as it is put back in place. Pouring water with the supplied funnel avoids this inconvenience.

User reviews

Jack

Good product, bought an extra one as a spare

Comment from 12 November 2026 — Experience from 1 November 2026

Automatically translated — Show original (Dutch)
Goed produkt extra erbij gekocht als reserve
  • Eco-contribution included in the sale price.
  • Manufacturer reference: HG01-WT
  • GTIN / EAN: 4893351900602
HomeCineSolutions
Loading